1)絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)屏(ping)蔽層(ceng)(ceng)端(duan)部(bu)應力處(chu)理。外半導(dao)電(dian)層(ceng)(ceng)端(duan)部(bu)用(yong)砂紙打(da)(da)磨(mo)或(huo)切削成45°小斜坡,打(da)(da)磨(mo)或(huo)切削后,半導(dao)電(dian)層(ceng)(ceng)端(duan)口平(ping)齊,坡面應平(ping)整光潔,與(yu)絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)層(ceng)(ceng)圓滑(hua)過渡,處(chu)理中(zhong)不得損傷絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)層(ceng)(ceng)。絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)端(duan)部(bu)應力處(chu)理前,用(yong)絕(jue)(jue)(jue)緣(yuan)(yuan)(yuan)自粘帶粘面朝外將(jiang)電(dian)纜三相線芯端(duan)頭包扎好,以防削切反應力錐時傷到導(dao)體。
2)清潔絕(jue)(jue)(jue)緣表(biao)面(mian)。用清潔紙將絕(jue)(jue)(jue)緣表(biao)面(mian)擦凈,應從絕(jue)(jue)(jue)緣端口向外半(ban)導電層方向擦抹,不能反(fan)復(fu)擦。擦凈后用一塊干凈的布(bu)或紙再次擦抹絕(jue)(jue)(jue)緣表(biao)面(mian),檢查(cha)布(bu)或紙上無(wu)炭(tan)痕時方為合格。
3)包(bao)繞應力疏(shu)散膠(jiao)(jiao)。將黃(huang)色菱形應力疏(shu)解膠(jiao)(jiao)拉(la)(la)薄拉(la)(la)窄,將半導電層(ceng)與絕緣(yuan)之間臺階繞包(bao)填平(ping),各壓絕緣(yuan)和半導電層(ceng)10mm,繞包(bao)的應力疏(shu)散膠(jiao)(jiao)端口應平(ping)齊。涂(tu)硅(gui)脂(zhi)時,不要涂(tu)在應力疏(shu)散膠(jiao)(jiao)上。
4)熱(re)縮應力控制管。根據圖紙尺(chi)寸(cun)和工藝要求,將應力控制管套(tao)在金(jin)屬屏蔽層上,與金(jin)屬屏蔽層搭接20mm,不得(de)隨意改變結構和尺(chi)寸(cun),從下端(duan)開始向電纜末端(duan)熱(re)縮。加熱(re)時,火焰不得(de)過(guo)猛,應溫火均勻加熱(re),使其自然收(shou)縮到位(wei)。